<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Rugged Design Archives - Vacuum Pump Rebuilders</title>
	<atom:link href="https://vacuumpumprebuilders.com/rugged-design/feed/" rel="self" type="application/rss+xml" />
	<link>https://vacuumpumprebuilders.com/rugged-design/</link>
	<description>Rebuilt Refurbished Repaired</description>
	<lastBuildDate>Tue, 05 Oct 2021 22:28:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.1.1</generator>

<image>
	<url>https://vacuumpumprebuilders.com/wp-content/uploads/2020/06/site_icon_vpr_white-150x150.png</url>
	<title>Rugged Design Archives - Vacuum Pump Rebuilders</title>
	<link>https://vacuumpumprebuilders.com/rugged-design/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Stokes 622 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-622-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 10 Mar 2020 03:55:59 +0000</pubDate>
				<category><![CDATA[Stokes Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1053</guid>

					<description><![CDATA[<p>Stokes 622 Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 622 booster pumps offer a pumping speed range from 3000 cfm to 3900 cfm. Stokes 622 (Process Isolation) booster pump is water cooled with 5 mechanical seals for [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-622-booster-pump/">Stokes 622 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="300" height="300" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump-300x300.jpg" alt="Edwards Stokes 622 Booster Pump" class="wp-image-1055 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump-150x150.jpg 150w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump.jpg 400w" sizes="(max-width: 300px) 100vw, 300px" /></figure><div class="wp-block-media-text__content">
<p><strong>Stokes 622</strong> Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available.  <strong>Stokes 622</strong> booster pumps offer a pumping speed range from 3000 cfm to 3900 cfm. </p>



<p><strong>Stokes 622 (Process Isolation)</strong> booster pump is water cooled with 5 mechanical seals for optimum protection.</p>
</div></div>



<p></p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Stokes 622 Booster Pump Specifications   </h2>



<table id="tablepress-9" class="tablepress tablepress-id-9">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">622</th><th class="column-4">622 PIB<br />
(Process Isolation)<br />
</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 1800 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">N/A</td><td class="column-4">N/A</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 2750 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">5100 | 3000</td><td class="column-4">5100 | 3000</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Displacement 3000 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">5525 | 2350</td><td class="column-4">5525 | 2350</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Displacement 3600 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">6630 | 3900</td><td class="column-4">6630 | 3900</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">8 inch ASA/ANSI</td><td class="column-4">8 inch ASA/ANSI</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Max pressure differential</td><td class="column-2">mbar | torr</td><td class="column-3">333 | 250</td><td class="column-4">333 | 250</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Max temp rise</td><td class="column-2">C | F</td><td class="column-3">121 | 250</td><td class="column-4">121 | 250</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Max discharge temperature</td><td class="column-2">C | F</td><td class="column-3">177 | 350</td><td class="column-4">177 | 350</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Weight bare shaft</td><td class="column-2">kg | lbs</td><td class="column-3">335 | 740</td><td class="column-4">335 | 740</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight TEFC <br />
direct drive</td><td class="column-2">kg | lbs</td><td class="column-3">617 | 1360</td><td class="column-4">625 | 1370</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">18 | 25</td><td class="column-4">18 | 25</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">18 | 25</td><td class="column-4">18 | 25</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Oil capacity <br />
horizontal flow</td><td class="column-2">litre/gal</td><td class="column-3">1.9 | 0.51</td><td class="column-4">1.9 | 0.51</td>
</tr>
<tr class="row-15 odd">
	<td class="column-1">Oil capacity <br />
vertical flow</td><td class="column-2">litre/gal</td><td class="column-3">4.1 | 1.1</td><td class="column-4">4.1 | 1.1</td>
</tr>
<tr class="row-16 even">
	<td class="column-1">Noise level<br />
at 50 Hz</td><td class="column-2">dBA</td><td class="column-3">< 82</td><td class="column-4">< 82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-9 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Stokes 622 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Range of 2750rpm to 3600rpm</li><li>Horizontal or vertical flow configurations</li><li>Noise level &lt;82 dB(A)</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">Stokes 622 Booster Pump Applications</h2>



<ul><li> Automotive</li><li>Chemical processing</li><li>Heat treatment</li><li>Leak detection</li><li>Metallurgy</li><li>PET processing</li><li>Pharmaceuticals</li><li>Thermal processing</li><li>Transformer drying</li><li>Vacuum Coating</li><li>Vacuum melting</li><li>Pharmaceuticals  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf">Stokes Booster Product Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf">Edwards Stokes Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-622-booster-pump/">Stokes 622 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Stokes 615 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-615-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 10 Mar 2020 03:40:10 +0000</pubDate>
				<category><![CDATA[Stokes Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1051</guid>

					<description><![CDATA[<p>Stokes 615 Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 615 booster pumps offer a pumping speed range from 1300 cfm to 2600 cfm. Stokes 615 PIB (Process Isolation) booster pump and the Stokes 615 (By-pass) offer a [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-615-booster-pump/">Stokes 615 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump.jpg" alt="Stokes 6 Mechanical Booster Pump" class="wp-image-1047 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Stokes 615</strong> Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available.  <strong>Stokes 615</strong> booster pumps offer a pumping speed range from 1300 cfm to 2600 cfm.  </p>



<p><strong>Stokes 615 PIB (Process Isolation)</strong> booster pump and the <strong>Stokes 615 (By-pass)</strong> offer a pumping speed range from 2000 cfm to 2600 cfm.   </p>
</div></div>



<p></p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Stokes 615 Booster Pump Specifications   </h2>



<table id="tablepress-8" class="tablepress tablepress-id-8">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">615</th><th class="column-4">615 PIB<br />
(Process Isolation)</th><th class="column-5">615 BP<br />
(By-pass)</th><th class="column-6">615 BP PIB<br />
</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 1800 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">2210 | 1300</td><td class="column-4"> N/A</td><td class="column-5">2210 | 2000</td><td class="column-6">N/A</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 2750 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">3375 | 2000</td><td class="column-4">3375 | 2000</td><td class="column-5">3375 | 2000</td><td class="column-6">3375 | 2000</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Displacement 3000 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">3685 | 2170</td><td class="column-4">3685 | 2170</td><td class="column-5">3685 | 2170</td><td class="column-6">3685 | 2170</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Displacement 3600 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">4420 | 2600</td><td class="column-4">4420 | 2600</td><td class="column-5">4420 | 2600</td><td class="column-6">4420 | 2600</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">8 inch ASA/ANSI</td><td class="column-4">8 inch ASA/ANSI</td><td class="column-5">8 inch ASA/ANSI</td><td class="column-6">8 inch ASA/ANSI</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Max pressure differential</td><td class="column-2">mbar | torr</td><td class="column-3">506 | 380</td><td class="column-4">506 | 380</td><td class="column-5">N/A</td><td class="column-6">N/A</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Max temp rise</td><td class="column-2">C | F</td><td class="column-3">135 | 275</td><td class="column-4">135 | 275</td><td class="column-5">135 | 275</td><td class="column-6">135 | 275</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Max discharge temperature</td><td class="column-2">C | F</td><td class="column-3">191 | 375</td><td class="column-4">191 | 375</td><td class="column-5">191 | 375</td><td class="column-6">191 | 375</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Weight bare shaft</td><td class="column-2">kg | lbs</td><td class="column-3">234 | 515</td><td class="column-4">234 | 515</td><td class="column-5">284 | 625</td><td class="column-6">284 | 625</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight TEFC <br />
direct drive</td><td class="column-2">kg | lbs</td><td class="column-3">390 | 860</td><td class="column-4">297 | 875</td><td class="column-5">530 | 1170</td><td class="column-6">538 | 1185</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10</td><td class="column-4">11 | 15</td><td class="column-5">18 | 25</td><td class="column-6">18 | 25</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">11 | 15</td><td class="column-4">11 | 15</td><td class="column-5">18 | 25</td><td class="column-6">18 | 25</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Oil capacity <br />
horizontal flow</td><td class="column-2">litre/gal</td><td class="column-3">1.9 | 0.51</td><td class="column-4">1.9 | 0.51</td><td class="column-5">1.9 | 0.51</td><td class="column-6">1.9 | 0.51</td>
</tr>
<tr class="row-15 odd">
	<td class="column-1">Oil capacity <br />
vertical flow</td><td class="column-2">litre/gal</td><td class="column-3">4.1 | 1.1</td><td class="column-4">4.1 | 1.1</td><td class="column-5">4.1 | 1.1</td><td class="column-6">4.1 | 1.1</td>
</tr>
<tr class="row-16 even">
	<td class="column-1">Noise level<br />
at 50 Hz</td><td class="column-2">dBA</td><td class="column-3">75</td><td class="column-4">75</td><td class="column-5">< 85</td><td class="column-6">< 85</td>
</tr>
</tbody>
</table>
<!-- #tablepress-8 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Stokes 615 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Range of 180rpm to 3600rpm</li><li>Horizontal or vertical flow configurations</li><li>615 Process Isolation booster model</li><li>615 By-pass booster model</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">Stokes 615 Booster Pump Applications</h2>



<ul><li> Automotive</li><li>Chemical processing</li><li>Heat treatment</li><li>Leak detection</li><li>Metallurgy</li><li>PET processing</li><li>Pharmaceuticals</li><li>Thermal processing</li><li>Transformer drying</li><li>Vacuum Coating</li><li>Vacuum melting</li><li>Pharmaceuticals  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf">Stokes Booster Product Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf">Edwards Stokes Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-615-booster-pump/">Stokes 615 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Stokes 607 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-607-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 10 Mar 2020 01:20:10 +0000</pubDate>
				<category><![CDATA[Stokes Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1046</guid>

					<description><![CDATA[<p>Stokes 607 Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 607 booster pumps offer a pumping speed range from 612 cfm to 1224 cfm.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-607-booster-pump/">Stokes 607 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump.jpg" alt="Stokes 607 Mechanical Booster Pump" class="wp-image-1054 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Stokes 607</strong> Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 607 booster pumps offer a pumping speed range from 612 cfm to 1224 cfm.</p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Stokes 607 Booster Pump Specifications   </h2>



<table id="tablepress-7" class="tablepress tablepress-id-7">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">607</th><th class="column-4">607 PIB<br />
(Process Isolation)</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 1800 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">1040 | 612</td><td class="column-4"> N/A</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 2750 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">1589 | 935</td><td class="column-4">1589 | 935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Displacement 3000 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">1733 | 1020</td><td class="column-4">1733 | 1020</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Displacement 3600 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">2080 | 1224</td><td class="column-4">2080 | 1224</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">6 inch ASA/ANSI</td><td class="column-4">6 inch ASA/ANSI</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Max pressure differential</td><td class="column-2">mbar | torr</td><td class="column-3">506 | 380</td><td class="column-4">506 | 380</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Max temp rise</td><td class="column-2">C | F</td><td class="column-3">135 | 275</td><td class="column-4">135 | 275</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Max discharge temperature</td><td class="column-2">C | F</td><td class="column-3">191 | 375</td><td class="column-4">191 | 375</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Weight bare shaft</td><td class="column-2">kg | lbs</td><td class="column-3">215 | 475</td><td class="column-4">215 | 475</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight TEFC <br />
direct drive</td><td class="column-2">kg | lbs</td><td class="column-3">408 | 900</td><td class="column-4">408 | 900</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10</td><td class="column-4">7.5 | 10</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10</td><td class="column-4">7.5 | 10</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Oil capacity <br />
horizontal flow</td><td class="column-2">litre/gal</td><td class="column-3">1.9 | 0.51</td><td class="column-4">1.9 | 0.51</td>
</tr>
<tr class="row-15 odd">
	<td class="column-1">Oil capacity <br />
vertical flow</td><td class="column-2">litre/gal</td><td class="column-3">4.1 | 1.1</td><td class="column-4">4.1 | 1.1</td>
</tr>
<tr class="row-16 even">
	<td class="column-1">Noise level<br />
at 50 Hz</td><td class="column-2">dBA</td><td class="column-3">65</td><td class="column-4">70</td>
</tr>
</tbody>
</table>
<!-- #tablepress-7 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Stokes 607 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Range of 1800rpm to 3600rpm</li><li>Horizontal or vertical flow configurations</li><li>Rugged design</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">Stokes 607 Booster Pump Applications</h2>



<ul><li> Automotive</li><li>Chemical processing</li><li>Heat treatment</li><li>Leak detection</li><li>Metallurgy</li><li>PET processing</li><li>Pharmaceuticals</li><li>Thermal processing</li><li>Transformer drying</li><li>Vacuum Coating</li><li>Vacuum melting</li><li>Pharmaceuticals  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf">Stokes Booster Product Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf">Edwards Stokes Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-607-booster-pump/">Stokes 607 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 4000 &#8211; 10000 Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-4000-10000-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Wed, 04 Mar 2020 18:53:29 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=971</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 4000-6500-7900-8000-10000 Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&#160; With bi-directional rotation, the 4000-6500-7900-8000-10000 models can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-4000-10000-booster/">Kinney 4000 &#8211; 10000 Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_4000.jpg" alt="Kinney 4000 Vacuum Booster Pump" class="wp-image-908 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_4000.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_4000-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_4000-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill <strong>4000-6500-7900-8000-10000  </strong> </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&nbsp; With bi-directional rotation, the<strong><strong> 4000-6500-7900-8000-10000 </strong></strong>models can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Kinney  4000 &#8211; 10000  Booster Pump Specifications   </h2>



<table id="tablepress-15" class="tablepress tablepress-id-15">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">4000</th><th class="column-4">6500</th><th class="column-5">7900</th><th class="column-6">8000</th><th class="column-7">10000</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2">cfm</td><td class="column-3">890-4000</td><td class="column-4">1400-6400</td><td class="column-5">1800-8000</td><td class="column-6">2100-9500</td><td class="column-7">2800-10000</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement</td><td class="column-2">m3/h</td><td class="column-3">1512-6796</td><td class="column-4">2379-10874</td><td class="column-5">3058-13592</td><td class="column-6">3568-16141</td><td class="column-7">4757-16990</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td><td class="column-7">3600</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">lbs</td><td class="column-3">4200</td><td class="column-4">4900</td><td class="column-5">5400</td><td class="column-6">5900</td><td class="column-7">6850</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td><td class="column-7"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-15 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Kinney  4000 &#8211; 10000  Booster Pump Features </h2>



<ul><li>4000 to 10000 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow <ul><li>Mechanical or Slinger seals</li><li>Integral Pressure Lubrication</li></ul></li><li>Horizontal flow <ul><li>Mechanical or Slinger seals</li><li> Integral Pressure Lubrication </li></ul></li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Drive Shaft: SAE 4140 forged alloy steel</li><li>Low noise &#8211; 82 dB(A) or less     </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Kinney  4000 &#8211; 10000  Booster Pump Applications</h2>



<ul><li>Supercharging Vacuum Systems</li><li>Vacuum Drying</li><li>Dehydration</li><li>Packaging</li><li>Distillation</li><li>Vacuum Furnace  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/boosters_4000_datasheet.pdf">Kinney Vacuum Boosters 4000-6500-7900-8000-10000 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/boosters_4000_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-4000-10000-booster/">Kinney 4000 &#8211; 10000 Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 3200 &#8211; 7300 Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-3200-7300-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 03 Mar 2020 22:40:34 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=965</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&#160; With bi-directional rotation, the 3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 &#160; models can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-3200-7300-booster/">Kinney 3200 &#8211; 7300 Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_3200.jpg" alt="Kinney 3200 Vacuum Boosters Pump" class="wp-image-907 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_3200.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_3200-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_3200-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill  <strong>  3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 </strong> </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&nbsp; With bi-directional rotation, the <strong> <strong> 3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 &nbsp;</strong> </strong>models can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Tuthill Kinney 3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 Booster Pump Specifications   </h2>



<table id="tablepress-14" class="tablepress tablepress-id-14">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">3200</th><th class="column-4">4200</th><th class="column-5">5400</th><th class="column-6">7300</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2">cfm</td><td class="column-3">800-3200</td><td class="column-4">1000-4200</td><td class="column-5">1400-5700</td><td class="column-6">1800-7400</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement</td><td class="column-2">m3/h</td><td class="column-3">1359-5437</td><td class="column-4">1699-7136</td><td class="column-5">2379-9684</td><td class="column-6">3058-12573</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">lbs</td><td class="column-3">2050</td><td class="column-4">2350</td><td class="column-5">2560</td><td class="column-6">3250</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-14 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Tuthill Kinney 3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 Booster Pump Features </h2>



<ul><li>3200 to 7300 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow mechanical seals</li><li>Horizontal flow mechanical seals</li><li>Vertical flow slinger seals</li><li>Horizontal flow slinger seals</li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Low noise &#8211; 82 dB(A) or less   </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Tuthill Kinney 3200 &#8211; 4200 &#8211; 5400 &#8211; 7300 Booster Pump Applications</h2>



<ul><li>Supercharging Vacuum Systems</li><li>Vacuum Drying</li><li>Dehydration</li><li>Packaging</li><li>Distillation</li><li>Vacuum Furnace  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_3200_datasheet.pdf"> Kinney Vacuum Boosters 3200-4200-5400-7300 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_3200_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/manual_3200C.pdf">Kinney Vacuum Boosters 3200 &#8211; 7300 Manual </a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/manual_3200C.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-3200-7300-booster/">Kinney 3200 &#8211; 7300 Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 1800 &#8211; 4500 Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-1800-4500-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 03 Mar 2020 21:25:49 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=960</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 1800 &#8211; 4500&#160; Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&#160; With bi-directional rotation, the 1800 &#8211; 4500&#160; models can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum boosters are available with flange adapters for mounting a [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-1800-4500-booster/">Kinney 1800 &#8211; 4500 Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_1800.jpg" alt="Kinney 1800 Vacuum Booster Pumps" class="wp-image-906 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_1800.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_1800-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_1800-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill  <strong> 1800 &#8211; 4500&nbsp;</strong>  </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&nbsp; With bi-directional rotation, the <strong> <strong> 1800 &#8211; 4500&nbsp;</strong> </strong>models can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Tuthill Kinney <strong> </strong>1800 &#8211; 4500<strong><strong>&nbsp;</strong></strong>  Booster Pump Specifications   </h2>



<table id="tablepress-13" class="tablepress tablepress-id-13">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">1800</th><th class="column-4">2200</th><th class="column-5">2900</th><th class="column-6">3600</th><th class="column-7">4500</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">680-1800 | 1155-3058</td><td class="column-4">860-2300 | 1461-3908</td><td class="column-5">1130-3000 | 1920-5097</td><td class="column-6">1400-3600 | 2379-6116</td><td class="column-7">1730-4500 | 2939-7646</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td><td class="column-7">3600</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Weight</td><td class="column-2">lbs</td><td class="column-3">1,150</td><td class="column-4">1255</td><td class="column-5">1390</td><td class="column-6">1540</td><td class="column-7">1720</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td><td class="column-7"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-13 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Tuthill Kinney  1800 &#8211; 4500&nbsp;  Booster Pump Features </h2>



<ul><li>1800 to 4500 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow mechanical seals</li><li>Horizontal flow mechanical seals</li><li>Vertical flow slinger seals</li><li>Horizontal flow slinger seals</li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Low noise &#8211; 82 dB(A) or less  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Tuthill Kinney  1800 &#8211; 4500&nbsp;  Booster Pump Applications</h2>



<ul><li>Supercharging Vacuum Systems</li><li>Vacuum Drying</li><li>Dehydration</li><li>Packaging</li><li>Distillation</li><li>Vacuum Furnace  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/boosters_1800_datasheet.pdf">Kinney Vacuum Boosters 1800-4500 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/boosters_1800_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-1800-4500-booster/">Kinney 1800 &#8211; 4500 Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 2700 Vacuum Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-2700-vacuum-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 03 Mar 2020 20:25:13 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=949</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 2700 Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&#160; With bi-directional rotation, the 2700 can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-2700-vacuum-booster/">Kinney 2700 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg" alt="Kinney 2700 Vacuum Booster Pump" class="wp-image-905 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill 2700 </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.&nbsp; With bi-directional rotation, the <strong>2700</strong> can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Tuthill Kinney 2700 Booster Pump Specifications   </h2>



<table id="tablepress-41" class="tablepress tablepress-id-41">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">2700</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">850-2700 | 1444-4587</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">10 | 250</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">790 | 358</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">750 | 340</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-41 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Tuthill Kinney 2700 Booster Pump Features </h2>



<ul><li>850 to 2700 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow mechanical seals</li><li>Horizontal flow mechanical seals</li><li>Vertical flow slinger seals</li><li>Horizontal flow slinger seals</li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Low noise &#8211; 82 dB(A) or less  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Tuthill Kinney 2700 Booster Pump Applications</h2>



<ul><li>Supercharging Vacuum Systems</li><li>Vacuum Drying</li><li>Dehydration</li><li>Packaging</li><li>Distillation</li><li>Vacuum Furnace  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-12" class="tablepress tablepress-id-12">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">850</th><th class="column-4">1200</th><th class="column-5">1600</th><th class="column-6">2000</th><th class="column-7">2700</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">270-850 | 459-1444</td><td class="column-4">400-1240 | 680-2107</td><td class="column-5">500-1600 | 850-2718</td><td class="column-6">650-2000 | 1104-3398</td><td class="column-7">850-2700 | 1444-4587</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity<br />
Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td><td class="column-4">4 | 3.79</td><td class="column-5">4 | 3.79</td><td class="column-6">4 | 3.79</td><td class="column-7">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity<br />
Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td><td class="column-4">2.5 | 2.37</td><td class="column-5">2.5 | 2.37</td><td class="column-6">2.5 | 2.37</td><td class="column-7">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">4 | 100</td><td class="column-4">4 | 100</td><td class="column-5">6 | 150</td><td class="column-6">8 | 200</td><td class="column-7">10 | 250</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td><td class="column-7">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">260 | 118</td><td class="column-4">300 | 136</td><td class="column-5">580 |263</td><td class="column-6">685 |310</td><td class="column-7">790 | 358</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">240 | 109</td><td class="column-4">280 | 127</td><td class="column-5">540 | 245</td><td class="column-6">645 |293</td><td class="column-7">750 | 340</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td><td class="column-7"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-12 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf">Kinney MD Booster Pump 2700 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf">Manual Tuthill Kinney Boosters 2700</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-2700-vacuum-booster/">Kinney 2700 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 2000 Vacuum Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-2000-vacuum-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 03 Mar 2020 20:20:52 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=946</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 2000 Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.  With bi-directional rotation, the 2000 can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-2000-vacuum-booster/">Kinney 2000 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg" alt="Kinney 2000 Vacuum Booster Pump" class="wp-image-905 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill 2000 </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.  With bi-directional rotation, the <strong>2000</strong> can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Tuthill Kinney 2000 Booster Pump Specifications   </h2>



<table id="tablepress-40" class="tablepress tablepress-id-40">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">2000</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">650-2000 | 1104-3398</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">8 | 200</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">685 |310</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">645 |293</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-40 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Tuthill Kinney 2000 Booster Pump Features </h2>



<ul><li>650 to 2000 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow mechanical seals</li><li>Horizontal flow mechanical seals</li><li>Vertical flow slinger seals</li><li>Horizontal flow slinger seals</li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Low noise &#8211; 82 dB(A) or less</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Tuthill Kinney 2000 Booster Pump Applications</h2>



<ul><li>Supercharging Vacuum Systems</li><li>Vacuum Drying</li><li>Dehydration</li><li>Packaging</li><li>Distillation</li><li>Vacuum Furnace  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-12-no-2" class="tablepress tablepress-id-12">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">850</th><th class="column-4">1200</th><th class="column-5">1600</th><th class="column-6">2000</th><th class="column-7">2700</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">270-850 | 459-1444</td><td class="column-4">400-1240 | 680-2107</td><td class="column-5">500-1600 | 850-2718</td><td class="column-6">650-2000 | 1104-3398</td><td class="column-7">850-2700 | 1444-4587</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity<br />
Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td><td class="column-4">4 | 3.79</td><td class="column-5">4 | 3.79</td><td class="column-6">4 | 3.79</td><td class="column-7">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity<br />
Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td><td class="column-4">2.5 | 2.37</td><td class="column-5">2.5 | 2.37</td><td class="column-6">2.5 | 2.37</td><td class="column-7">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">4 | 100</td><td class="column-4">4 | 100</td><td class="column-5">6 | 150</td><td class="column-6">8 | 200</td><td class="column-7">10 | 250</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td><td class="column-7">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">260 | 118</td><td class="column-4">300 | 136</td><td class="column-5">580 |263</td><td class="column-6">685 |310</td><td class="column-7">790 | 358</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">240 | 109</td><td class="column-4">280 | 127</td><td class="column-5">540 | 245</td><td class="column-6">645 |293</td><td class="column-7">750 | 340</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td><td class="column-7"><82</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf">Kinney MD Booster Pump 2000 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf">Manual Tuthill Kinney Boosters 2000</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-2000-vacuum-booster/">Kinney 2000 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 1200 Vacuum Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-1200-vacuum-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 03 Mar 2020 20:14:22 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=943</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 1200 Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.  With bi-directional rotation, the 1200 can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-1200-vacuum-booster/">Kinney 1200 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg" alt="Kinney 1200 Vacuum Booster Pump" class="wp-image-905 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill 1200 </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.  With bi-directional rotation, the <strong>1200</strong> can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Tuthill Kinney 1200 Booster Pump Specifications   </h2>



<table id="tablepress-38" class="tablepress tablepress-id-38">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">1200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">400-1240 | 680-2107</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">4 | 100</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">300 | 136</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">280 | 127</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-38 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Tuthill Kinney 1200 Booster Pump Features </h2>



<ul><li>400 to 1240 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow mechanical seals</li><li>Horizontal flow mechanical seals</li><li>Vertical flow slinger seals</li><li>Horizontal flow slinger seals</li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Low noise &#8211; 82 dB(A) or less </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Tuthill Kinney 1200 Booster Pump Applications</h2>



<ul><li>Supercharging Vacuum Systems</li><li>Vacuum Drying</li><li>Dehydration</li><li>Packaging</li><li>Distillation</li><li>Vacuum Furnace  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-12-no-3" class="tablepress tablepress-id-12">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">850</th><th class="column-4">1200</th><th class="column-5">1600</th><th class="column-6">2000</th><th class="column-7">2700</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">270-850 | 459-1444</td><td class="column-4">400-1240 | 680-2107</td><td class="column-5">500-1600 | 850-2718</td><td class="column-6">650-2000 | 1104-3398</td><td class="column-7">850-2700 | 1444-4587</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity<br />
Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td><td class="column-4">4 | 3.79</td><td class="column-5">4 | 3.79</td><td class="column-6">4 | 3.79</td><td class="column-7">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity<br />
Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td><td class="column-4">2.5 | 2.37</td><td class="column-5">2.5 | 2.37</td><td class="column-6">2.5 | 2.37</td><td class="column-7">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">4 | 100</td><td class="column-4">4 | 100</td><td class="column-5">6 | 150</td><td class="column-6">8 | 200</td><td class="column-7">10 | 250</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td><td class="column-7">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">260 | 118</td><td class="column-4">300 | 136</td><td class="column-5">580 |263</td><td class="column-6">685 |310</td><td class="column-7">790 | 358</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">240 | 109</td><td class="column-4">280 | 127</td><td class="column-5">540 | 245</td><td class="column-6">645 |293</td><td class="column-7">750 | 340</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td><td class="column-7"><82</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf">Kinney MD Booster Pump 1200 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf">Manual Tuthill Kinney Boosters 1200</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-1200-vacuum-booster/">Kinney 1200 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kinney 850 Vacuum Booster</title>
		<link>https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-850-vacuum-booster/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 03 Mar 2020 19:59:06 +0000</pubDate>
				<category><![CDATA[Kinney Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<category><![CDATA[Tuthill]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=939</guid>

					<description><![CDATA[<p>The Kinney/Tuthill 850 Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.  With bi-directional rotation, the 850 can offer vertical and horizontal flow configurations with mechanical or slinger seals. All&#160;Kinney/Tuthill&#160;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-850-vacuum-booster/">Kinney 850 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg" alt="Kinney 850 Vacuum Booster Pump" class="wp-image-905 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/kinney_MD_850-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p>The <strong>Kinney/Tuthill 850 </strong>Mechanical Vacuum Boosters are designed to extend vacuum pump performance to provide faster pumping speeds and deeper vacuum levels.  With bi-directional rotation, the <strong>850</strong> can offer vertical and horizontal flow configurations with mechanical or slinger seals.  </p>
</div></div>



<p> All&nbsp;<strong>Kinney/Tuthill</strong>&nbsp;mechanical vacuum boosters are available with flange adapters for mounting a NEMA C-face motor (up to 75HP) or an IEC D-flange motor (up to 55kW) directly to the vacuum booster.  </p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Tuthill Kinney 850 Booster Pump Specifications   </h2>



<table id="tablepress-37" class="tablepress tablepress-id-37">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">850</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">270-850 | 459-1444</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">4 | 100</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">260 | 118</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">240 | 109</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-37 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">  Tuthill Kinney 850 Booster Pump Features </h2>



<ul><li>270 to 850 cfm pumping speed</li><li>Bi-directional rotation</li><li>Vertical flow mechanical seals</li><li>Horizontal flow mechanical seals</li><li>Vertical flow slinger seals</li><li>Horizontal flow slinger seals</li><li>Cast Iron housing</li><li>Cast Iron end plates and fittings</li><li>Ductile iron rotors and shafts</li><li>Low noise &#8211; 82 dB(A) or less </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">    Tuthill Kinney 850 Booster Pump Applications</h2>



<ul><li>Chemical industry</li><li>Petrochemical industry</li><li>Plastics industry</li><li>Semiconductor industry</li><li>Wood Composites manufacturing</li><li>Food processing</li><li>Vacuum furnace applications</li><li>General industrial applications  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-12-no-4" class="tablepress tablepress-id-12">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">850</th><th class="column-4">1200</th><th class="column-5">1600</th><th class="column-6">2000</th><th class="column-7">2700</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement</td><td class="column-2"> cfm | m3/h</td><td class="column-3">270-850 | 459-1444</td><td class="column-4">400-1240 | 680-2107</td><td class="column-5">500-1600 | 850-2718</td><td class="column-6">650-2000 | 1104-3398</td><td class="column-7">850-2700 | 1444-4587</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Oil Capacity<br />
Vertical</td><td class="column-2">qt | L</td><td class="column-3">4 | 3.79</td><td class="column-4">4 | 3.79</td><td class="column-5">4 | 3.79</td><td class="column-6">4 | 3.79</td><td class="column-7">4 | 3.79</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Oil Capacity<br />
Horizontal</td><td class="column-2">qt | L</td><td class="column-3">2.5 | 2.37</td><td class="column-4">2.5 | 2.37</td><td class="column-5">2.5 | 2.37</td><td class="column-6">2.5 | 2.37</td><td class="column-7">2.5 | 2.37</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Port Size</td><td class="column-2">inch  | mm</td><td class="column-3">4 | 100</td><td class="column-4">4 | 100</td><td class="column-5">6 | 150</td><td class="column-6">8 | 200</td><td class="column-7">10 | 250</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Max RPM</td><td class="column-2"></td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td><td class="column-7">3600</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Weight Vertical</td><td class="column-2">lb | kg</td><td class="column-3">260 | 118</td><td class="column-4">300 | 136</td><td class="column-5">580 |263</td><td class="column-6">685 |310</td><td class="column-7">790 | 358</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Weight Horizontal</td><td class="column-2">lb | kg</td><td class="column-3">240 | 109</td><td class="column-4">280 | 127</td><td class="column-5">540 | 245</td><td class="column-6">645 |293</td><td class="column-7">750 | 340</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Noise</td><td class="column-2">DbA</td><td class="column-3"><82</td><td class="column-4"><82</td><td class="column-5"><82</td><td class="column-6"><82</td><td class="column-7"><82</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf">Kinney MD Booster Pump 850 Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/10/booster_850_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf">Manual Tuthill Kinney Boosters 850</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/manual_kinney_boosters_150.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/kinney-booster-pumps/kinney-850-vacuum-booster/">Kinney 850 Vacuum Booster</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
