<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Edwards Booster Pumps - Vacuum Pump Rebuilders</title>
	<atom:link href="https://vacuumpumprebuilders.com/roots-blowers-booster-pumps/edwards-booster-pumps/feed/" rel="self" type="application/rss+xml" />
	<link>https://vacuumpumprebuilders.com/roots-blowers-booster-pumps/edwards-booster-pumps/</link>
	<description>Rebuilt Refurbished Repaired</description>
	<lastBuildDate>Fri, 01 Oct 2021 03:52:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2</generator>

<image>
	<url>https://vacuumpumprebuilders.com/wp-content/uploads/2020/06/site_icon_vpr_white-150x150.png</url>
	<title>Edwards Booster Pumps - Vacuum Pump Rebuilders</title>
	<link>https://vacuumpumprebuilders.com/roots-blowers-booster-pumps/edwards-booster-pumps/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Edwards EH4200 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh4200-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Thu, 27 Feb 2020 22:37:50 +0000</pubDate>
				<category><![CDATA[Edwards Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots/Booster Pump]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=871</guid>

					<description><![CDATA[<p>Edwards EH4200 mechanical booster pump with a pumping speed of 4140 m3/h at 50 Hz and 4985 m3/h at 60 Hz. This is an excellent pump for applications where high pumping speeds are required. EH booster pumps have universal voltage and air-cooled motors.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh4200-booster-pump/">Edwards EH4200 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH4200.jpg" alt="Edwards Mechanical Booster Pump EH4200" class="wp-image-859 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH4200.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH4200-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH4200-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Edwards EH4200 </strong>mechanical booster pump with a pumping speed of 4140 m<sup>3</sup>/h at 50 Hz and 4985 m<sup>3</sup>/h at 60 Hz.       This is an excellent pump for applications where high pumping speeds are required.  EH booster pumps have universal voltage and air-cooled motors.<strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH4200 Booster Pump Specifications   </h2>



<table id="tablepress-23" class="tablepress tablepress-id-23">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH4200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">4140 | 2440</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">4985 | 2935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 250</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">481 | 1058</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions (L x W x H)</td><td class="column-2">mm</td><td class="column-3">1336 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity gear case</td><td class="column-2">litre</td><td class="column-3">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity coupling cover</td><td class="column-2">litre</td><td class="column-3">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">250 | 1.1</td>
</tr>
</tbody>
</table>
<!-- #tablepress-23 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH 4200 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Hydrokinetic fluid drive</li><li>Fast pump down times</li><li>Reduced operating costs</li><li>Automatic overload protection</li><li>Simple installation</li><li>Quiet with low vibration</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">  Edwards EH 4200 Booster Pump Applications</h2>



<ul><li>Vacuum metallurgy</li><li>Vacuum distillation</li><li>Vacuum packaging</li><li>Steel Degassing</li><li>Thin film coating</li><li>Vacuum impregnation</li><li>Oil drying and de-gassing</li><li>Space simulation</li><li>Pharmaceutical freeze drying</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-6" class="tablepress tablepress-id-6">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH250</th><th class="column-4">EH500</th><th class="column-5">EH1200</th><th class="column-6">EH2600</th><th class="column-7">EH4200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">310 | 185</td><td class="column-4">505 | 300</td><td class="column-5">1195 | 715</td><td class="column-6">2590 | 1525</td><td class="column-7">4140 | 2440</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">375 | 220</td><td class="column-4">605 | 335</td><td class="column-5">1435 | 845</td><td class="column-6">3110 | 1830</td><td class="column-7">4985 | 2935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 63</td><td class="column-4">ISO 100</td><td class="column-5">ISO 160</td><td class="column-6">ISO 160</td><td class="column-7">ISO 250</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">69 | 152</td><td class="column-4">106 | 233</td><td class="column-5">149 | 328</td><td class="column-6">401 | 882</td><td class="column-7">481 | 1058</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions<br />
(L x W x H)</td><td class="column-2">mm</td><td class="column-3">705 x 305 x 272</td><td class="column-4">791 x 305 x 265</td><td class="column-5">953 x 380 x 334</td><td class="column-6">1156 x 522 x 479</td><td class="column-7">1336 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity<br />
gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td><td class="column-4">N/A</td><td class="column-5">1.25</td><td class="column-6">3.5</td><td class="column-7">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity<br />
coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td><td class="column-4">1.5</td><td class="column-5">2.4</td><td class="column-6">6.5</td><td class="column-7">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity<br />
shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td><td class="column-4">0.125</td><td class="column-5">0.125</td><td class="column-6">0.15</td><td class="column-7">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td><td class="column-4">air cooled</td><td class="column-5">120 | 0.53</td><td class="column-6">250 | 1.1</td><td class="column-7">250 | 1.1</td>
</tr>
</tbody>
</table>
<!-- #tablepress-6 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf">Edwards EH Booster Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf">Edwards EH Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh4200-booster-pump/">Edwards EH4200 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Edwards EH2600 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh2600-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Thu, 27 Feb 2020 22:32:34 +0000</pubDate>
				<category><![CDATA[Edwards Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots/Booster Pump]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=869</guid>

					<description><![CDATA[<p>Edwards EH2600 mechanical booster pump with a pumping speed of 2590 m3/h at 50 Hz and 3110 m3/h at 60 Hz. This is an excellent pump for applications where high pumping speeds are required. EH booster pumps have universal voltage and air-cooled motors.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh2600-booster-pump/">Edwards EH2600 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH2600.jpg" alt="Edwards Mechanical Booster Pump EH2600" class="wp-image-858 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH2600.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH2600-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH2600-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong> <strong>Edwards EH2600</strong> </strong>mechanical booster pump with a pumping speed of 2590 m<sup>3</sup>/h at 50 Hz and 3110 m<sup>3</sup>/h at 60 Hz.      This is an excellent pump for applications where high pumping speeds are required.  EH booster pumps have universal voltage and air-cooled motors.<strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH2600 Booster Pump Specifications   </h2>



<table id="tablepress-22" class="tablepress tablepress-id-22">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH2600</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2590 | 1525</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">3110 | 1830</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 160</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">401 | 882</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions (L x W x H)</td><td class="column-2">mm</td><td class="column-3">1156 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity gear case</td><td class="column-2">litre</td><td class="column-3">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity coupling cover</td><td class="column-2">litre</td><td class="column-3">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">250 | 1.1</td>
</tr>
</tbody>
</table>
<!-- #tablepress-22 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH 2600 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Hydrokinetic fluid drive</li><li>Fast pump down times</li><li>Reduced operating costs</li><li>Automatic overload protection</li><li>Simple installation</li><li>Quiet with low vibration</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">  Edwards EH 2600 Booster Pump Applications</h2>



<ul><li>Vacuum metallurgy</li><li>Vacuum distillation</li><li>Vacuum packaging</li><li>Steel Degassing</li><li>Thin film coating</li><li>Vacuum impregnation</li><li>Oil drying and de-gassing</li><li>Space simulation</li><li>Pharmaceutical freeze drying</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-6-no-2" class="tablepress tablepress-id-6">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH250</th><th class="column-4">EH500</th><th class="column-5">EH1200</th><th class="column-6">EH2600</th><th class="column-7">EH4200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">310 | 185</td><td class="column-4">505 | 300</td><td class="column-5">1195 | 715</td><td class="column-6">2590 | 1525</td><td class="column-7">4140 | 2440</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">375 | 220</td><td class="column-4">605 | 335</td><td class="column-5">1435 | 845</td><td class="column-6">3110 | 1830</td><td class="column-7">4985 | 2935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 63</td><td class="column-4">ISO 100</td><td class="column-5">ISO 160</td><td class="column-6">ISO 160</td><td class="column-7">ISO 250</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">69 | 152</td><td class="column-4">106 | 233</td><td class="column-5">149 | 328</td><td class="column-6">401 | 882</td><td class="column-7">481 | 1058</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions<br />
(L x W x H)</td><td class="column-2">mm</td><td class="column-3">705 x 305 x 272</td><td class="column-4">791 x 305 x 265</td><td class="column-5">953 x 380 x 334</td><td class="column-6">1156 x 522 x 479</td><td class="column-7">1336 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity<br />
gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td><td class="column-4">N/A</td><td class="column-5">1.25</td><td class="column-6">3.5</td><td class="column-7">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity<br />
coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td><td class="column-4">1.5</td><td class="column-5">2.4</td><td class="column-6">6.5</td><td class="column-7">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity<br />
shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td><td class="column-4">0.125</td><td class="column-5">0.125</td><td class="column-6">0.15</td><td class="column-7">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td><td class="column-4">air cooled</td><td class="column-5">120 | 0.53</td><td class="column-6">250 | 1.1</td><td class="column-7">250 | 1.1</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf">Edwards EH Booster Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf">Edwards EH Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh2600-booster-pump/">Edwards EH2600 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Edwards EH1200 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh1200-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Thu, 27 Feb 2020 22:24:22 +0000</pubDate>
				<category><![CDATA[Edwards Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots/Booster Pump]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=865</guid>

					<description><![CDATA[<p>Edwards EH1200 mechanical booster pump with a pumping speed of 1195 m3/h at 50 Hz and 1435 m3/h at 60 Hz. This is an excellent pump for applications where high pumping speeds are required. EH booster pumps have universal voltage and air-cooled motors.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh1200-booster-pump/">Edwards EH1200 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH1200.jpg" alt="Edwards Mechanical Booster Pump EH1200" class="wp-image-857 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH1200.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH1200-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH1200-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong> <strong>Edwards EH1200</strong></strong> mechanical booster pump with a pumping speed of 1195 m<sup>3</sup>/h at 50 Hz and 1435 m<sup>3</sup>/h at 60 Hz. <strong> </strong>  This is an excellent pump for applications where high pumping speeds are required.  EH booster pumps have universal voltage and air-cooled motors.<strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH1200 Booster Pump Specifications   </h2>



<table id="tablepress-21" class="tablepress tablepress-id-21">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH1200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1195 | 715</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1435 | 845</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 160</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">149 | 328</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions (L x W x H)</td><td class="column-2">mm</td><td class="column-3">953 x 380 x 334</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">3.0 | 4</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">3.0 | 4</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity gear case</td><td class="column-2">litre</td><td class="column-3">1.25</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity coupling cover</td><td class="column-2">litre</td><td class="column-3">2.4</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">120 | 0.53</td>
</tr>
</tbody>
</table>
<!-- #tablepress-21 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH 1200 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Hydrokinetic fluid drive</li><li>Fast pump down times</li><li>Reduced operating costs</li><li>Automatic overload protection</li><li>Simple installation</li><li>Quiet with low vibration</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">  Edwards EH 1200 Booster Pump Applications</h2>



<ul><li>Vacuum metallurgy</li><li>Vacuum distillation</li><li>Vacuum packaging</li><li>Steel Degassing</li><li>Thin film coating</li><li>Vacuum impregnation</li><li>Oil drying and de-gassing</li><li>Space simulation</li><li>Pharmaceutical freeze drying</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-6-no-3" class="tablepress tablepress-id-6">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH250</th><th class="column-4">EH500</th><th class="column-5">EH1200</th><th class="column-6">EH2600</th><th class="column-7">EH4200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">310 | 185</td><td class="column-4">505 | 300</td><td class="column-5">1195 | 715</td><td class="column-6">2590 | 1525</td><td class="column-7">4140 | 2440</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">375 | 220</td><td class="column-4">605 | 335</td><td class="column-5">1435 | 845</td><td class="column-6">3110 | 1830</td><td class="column-7">4985 | 2935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 63</td><td class="column-4">ISO 100</td><td class="column-5">ISO 160</td><td class="column-6">ISO 160</td><td class="column-7">ISO 250</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">69 | 152</td><td class="column-4">106 | 233</td><td class="column-5">149 | 328</td><td class="column-6">401 | 882</td><td class="column-7">481 | 1058</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions<br />
(L x W x H)</td><td class="column-2">mm</td><td class="column-3">705 x 305 x 272</td><td class="column-4">791 x 305 x 265</td><td class="column-5">953 x 380 x 334</td><td class="column-6">1156 x 522 x 479</td><td class="column-7">1336 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity<br />
gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td><td class="column-4">N/A</td><td class="column-5">1.25</td><td class="column-6">3.5</td><td class="column-7">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity<br />
coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td><td class="column-4">1.5</td><td class="column-5">2.4</td><td class="column-6">6.5</td><td class="column-7">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity<br />
shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td><td class="column-4">0.125</td><td class="column-5">0.125</td><td class="column-6">0.15</td><td class="column-7">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td><td class="column-4">air cooled</td><td class="column-5">120 | 0.53</td><td class="column-6">250 | 1.1</td><td class="column-7">250 | 1.1</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf">Edwards EH Booster Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf">Edwards EH Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh1200-booster-pump/">Edwards EH1200 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Edwards EH500 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh500-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Thu, 27 Feb 2020 22:16:34 +0000</pubDate>
				<category><![CDATA[Edwards Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots/Booster Pump]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=862</guid>

					<description><![CDATA[<p>Edwards EH500 mechanical booster pump with a pumping speed of 505 m3/h at 50 Hz and 605 m3/h at 60 Hz. This is an excellent pump for applications where high pumping speeds are required. EH booster pumps have universal voltage and air-cooled motors.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh500-booster-pump/">Edwards EH500 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH500.jpg" alt="Edwards Mechanical Booster Pump EH500" class="wp-image-856 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH500.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH500-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH500-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Edwards EH500</strong>  mechanical booster pump with a pumping speed of 505 m<sup>3</sup>/h at 50 Hz and 605 m<sup>3</sup>/h at 60 Hz.   This is an excellent pump for applications where high pumping speeds are required.  EH booster pumps have universal voltage and air-cooled motors.<strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH500 Booster Pump Specifications   </h2>



<table id="tablepress-20" class="tablepress tablepress-id-20">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH500</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">505 | 300</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">605 | 335</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 100</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">106 | 233</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions (L x W x H)</td><td class="column-2">mm</td><td class="column-3">791 x 305 x 265</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td>
</tr>
</tbody>
</table>
<!-- #tablepress-20 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH 500 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Hydrokinetic fluid drive</li><li>Fast pump down times</li><li>Reduced operating costs</li><li>Automatic overload protection</li><li>Simple installation</li><li>Quiet with low vibration</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">  Edwards EH 500 Booster Pump Applications</h2>



<ul><li>Vacuum metallurgy</li><li>Vacuum distillation</li><li>Vacuum packaging</li><li>Steel Degassing</li><li>Thin film coating</li><li>Vacuum impregnation</li><li>Oil drying and de-gassing</li><li>Space simulation</li><li>Pharmaceutical freeze drying</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-6-no-4" class="tablepress tablepress-id-6">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH250</th><th class="column-4">EH500</th><th class="column-5">EH1200</th><th class="column-6">EH2600</th><th class="column-7">EH4200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">310 | 185</td><td class="column-4">505 | 300</td><td class="column-5">1195 | 715</td><td class="column-6">2590 | 1525</td><td class="column-7">4140 | 2440</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">375 | 220</td><td class="column-4">605 | 335</td><td class="column-5">1435 | 845</td><td class="column-6">3110 | 1830</td><td class="column-7">4985 | 2935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 63</td><td class="column-4">ISO 100</td><td class="column-5">ISO 160</td><td class="column-6">ISO 160</td><td class="column-7">ISO 250</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">69 | 152</td><td class="column-4">106 | 233</td><td class="column-5">149 | 328</td><td class="column-6">401 | 882</td><td class="column-7">481 | 1058</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions<br />
(L x W x H)</td><td class="column-2">mm</td><td class="column-3">705 x 305 x 272</td><td class="column-4">791 x 305 x 265</td><td class="column-5">953 x 380 x 334</td><td class="column-6">1156 x 522 x 479</td><td class="column-7">1336 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity<br />
gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td><td class="column-4">N/A</td><td class="column-5">1.25</td><td class="column-6">3.5</td><td class="column-7">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity<br />
coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td><td class="column-4">1.5</td><td class="column-5">2.4</td><td class="column-6">6.5</td><td class="column-7">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity<br />
shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td><td class="column-4">0.125</td><td class="column-5">0.125</td><td class="column-6">0.15</td><td class="column-7">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td><td class="column-4">air cooled</td><td class="column-5">120 | 0.53</td><td class="column-6">250 | 1.1</td><td class="column-7">250 | 1.1</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf">Edwards EH Booster Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf">Edwards EH Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh500-booster-pump/">Edwards EH500 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Edwards EH250 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh250-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Thu, 27 Feb 2020 22:08:34 +0000</pubDate>
				<category><![CDATA[Edwards Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots/Booster Pump]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=860</guid>

					<description><![CDATA[<p>Edwards EH250 mechanical booster pump with a pumping speed of 310 m3/h at 50 Hz and 375 m3/h at 60 Hz. This is an excellent pump for applications where high pumping speeds are required. EH booster pumps have universal voltage and air-cooled motors.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh250-booster-pump/">Edwards EH250 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH250.jpg" alt="Edwards Booster Pump EH250" class="wp-image-855 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH250.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH250-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/02/EH250-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Edwards EH250</strong> mechanical booster pump with a pumping speed of 310 m<sup>3</sup>/h at 50 Hz and 375 m<sup>3</sup>/h at 60 Hz.  This is an excellent pump for applications where high pumping speeds are required.  EH booster pumps have universal voltage and air-cooled motors.<strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH250 Booster Pump Specifications   </h2>



<table id="tablepress-19" class="tablepress tablepress-id-19">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH250</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">310 | 185</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">375 | 220</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 63</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">69 | 152</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions (L x W x H)</td><td class="column-2">mm</td><td class="column-3">705 x 305 x 272</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td>
</tr>
</tbody>
</table>
<!-- #tablepress-19 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Edwards EH 250 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Hydrokinetic fluid drive</li><li>Fast pump down times</li><li>Reduced operating costs</li><li>Automatic overload protection</li><li>Simple installation</li><li>Quiet with low vibration</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">  Edwards EH 250 Booster Pump Applications</h2>



<ul><li>Vacuum metallurgy</li><li>Vacuum distillation</li><li>Vacuum packaging</li><li>Steel Degassing</li><li>Thin film coating</li><li>Vacuum impregnation</li><li>Oil drying and de-gassing</li><li>Space simulation</li><li>Pharmaceutical freeze drying</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-6-no-5" class="tablepress tablepress-id-6">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">EH250</th><th class="column-4">EH500</th><th class="column-5">EH1200</th><th class="column-6">EH2600</th><th class="column-7">EH4200</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">310 | 185</td><td class="column-4">505 | 300</td><td class="column-5">1195 | 715</td><td class="column-6">2590 | 1525</td><td class="column-7">4140 | 2440</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">375 | 220</td><td class="column-4">605 | 335</td><td class="column-5">1435 | 845</td><td class="column-6">3110 | 1830</td><td class="column-7">4985 | 2935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">ISO 63</td><td class="column-4">ISO 100</td><td class="column-5">ISO 160</td><td class="column-6">ISO 160</td><td class="column-7">ISO 250</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">69 | 152</td><td class="column-4">106 | 233</td><td class="column-5">149 | 328</td><td class="column-6">401 | 882</td><td class="column-7">481 | 1058</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Dimensions<br />
(L x W x H)</td><td class="column-2">mm</td><td class="column-3">705 x 305 x 272</td><td class="column-4">791 x 305 x 265</td><td class="column-5">953 x 380 x 334</td><td class="column-6">1156 x 522 x 479</td><td class="column-7">1336 x 522 x 479</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Motor Power 50Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Motor Power 60Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3</td><td class="column-4">2.2 | 3</td><td class="column-5">3.0 | 4</td><td class="column-6">11.0 | 15</td><td class="column-7">11.0 | 15</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Oil capacity<br />
gear case</td><td class="column-2">litre</td><td class="column-3">N/A</td><td class="column-4">N/A</td><td class="column-5">1.25</td><td class="column-6">3.5</td><td class="column-7">3.5</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Oil capacity<br />
coupling cover</td><td class="column-2">litre</td><td class="column-3">1.5</td><td class="column-4">1.5</td><td class="column-5">2.4</td><td class="column-6">6.5</td><td class="column-7">6.5</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Oil capacity<br />
shaft seal res</td><td class="column-2">litre</td><td class="column-3">0.125</td><td class="column-4">0.125</td><td class="column-5">0.125</td><td class="column-6">0.15</td><td class="column-7">0.15</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Water cooling req</td><td class="column-2">L/h | gal/m</td><td class="column-3">air cooled</td><td class="column-4">air cooled</td><td class="column-5">120 | 0.53</td><td class="column-6">250 | 1.1</td><td class="column-7">250 | 1.1</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf">Edwards EH Booster Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/Edwards-EH-Booster-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf">Edwards EH Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-EH-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/edwards-booster-pumps/edwards-eh250-booster-pump/">Edwards EH250 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>