<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hermetically Sealed Motor Archives - Vacuum Pump Rebuilders</title>
	<atom:link href="https://vacuumpumprebuilders.com/hermetically-sealed-motor/feed/" rel="self" type="application/rss+xml" />
	<link>https://vacuumpumprebuilders.com/hermetically-sealed-motor/</link>
	<description>Rebuilt Refurbished Repaired</description>
	<lastBuildDate>Sun, 03 Oct 2021 05:20:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.1.1</generator>

<image>
	<url>https://vacuumpumprebuilders.com/wp-content/uploads/2020/06/site_icon_vpr_white-150x150.png</url>
	<title>Hermetically Sealed Motor Archives - Vacuum Pump Rebuilders</title>
	<link>https://vacuumpumprebuilders.com/hermetically-sealed-motor/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Leybold WS/WSU 2001 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-2001-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 20:32:27 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Hermetically Sealed Motor]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1040</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 2001 Roots vacuum pumps use air cooled hermetically canned motors. The Leybold WSU 2001 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-2001-roots-vacuum-pump/">Leybold WS/WSU 2001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001.jpg" alt="Leybold WS 2001 Roots Vacuum Pump" class="wp-image-992 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WS 2001</strong> Roots vacuum pumps use air cooled hermetically canned motors.  The <strong>Leybold WSU 2001</strong> Roots vacuum pumps are provided with an additional integrated pressure equalization line.    </p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Leybold WSU 2001 Roots Pump Specifications   </h2>



<table id="tablepress-31" class="tablepress tablepress-id-31">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><65</td>
</tr>
</tbody>
</table>
<!-- #tablepress-31 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Leybold WSU 2001 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;65 dB(A)</li><li>IP 20 Protection</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">   Leybold WSU 2001 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-2001-roots-vacuum-pump/">Leybold WS/WSU 2001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WS/WSU 1001 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-1001-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 20:02:39 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Hermetically Sealed Motor]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1037</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 1001 Roots vacuum pumps use air cooled hermetically canned motors. The Leybold WSU 1001 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-1001-roots-vacuum-pump/">Leybold WS/WSU 1001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001.jpg" alt="Leybold WS/WSU 1001 Roots Vacuum Pump" class="wp-image-1000 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p> <strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WS 1001 </strong>Roots vacuum pumps use air cooled hermetically canned motors.  The <strong>Leybold WSU 1001 </strong>Roots vacuum pumps are provided with an additional integrated pressure equalization line. <strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Leybold WSU 1001 Roots Pump Specifications   </h2>



<table id="tablepress-30" class="tablepress tablepress-id-30">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 1001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1000 | 589</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1200 | 707</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">4.0 | 5.4</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">4.4 | 6.0</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">1.75</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">1.8</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">100 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">228 | 502.7</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">233 | 513.8</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><60</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Leybold WSU 1001 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;60 dB(A)</li><li>IP 20 Protection</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">   Leybold WSU 1001 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17-no-2" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>
<!-- #tablepress-17-no-2 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-1001-roots-vacuum-pump/">Leybold WS/WSU 1001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WS/WSU 501 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-501-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 19:57:26 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Hermetically Sealed Motor]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1031</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 501 Roots vacuum pumps use air cooled hermetically canned motors. The Leybold WSU 501 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-501-roots-vacuum-pump/">Leybold WS/WSU 501 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501.jpg" alt="Leybold WS/WSU 501 Roots Vacuum Pump" class="wp-image-999 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WS 501 </strong>Roots vacuum pumps use air cooled hermetically canned motors.  The <strong>Leybold WSU 501 </strong>Roots vacuum pumps are provided with an additional integrated pressure equalization line.    </p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Leybold WSU 501 Roots Pump Specifications   </h2>



<table id="tablepress-29" class="tablepress tablepress-id-29">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 501</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">505 | 297.4</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">606 | 357</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.4 | 3.3</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.75</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.8</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">130 | 286.7</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">135 | 297.7</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><52</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size"> Leybold WSU 501 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;52 dB(A)</li><li>IP 20 Protection</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size">   Leybold WSU 501 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17-no-3" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>
<!-- #tablepress-17-no-3 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-501-roots-vacuum-pump/">Leybold WS/WSU 501 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>