<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Super User, Author at Vacuum Pump Rebuilders</title>
	<atom:link href="https://vacuumpumprebuilders.com/author/pump/feed/" rel="self" type="application/rss+xml" />
	<link>https://vacuumpumprebuilders.com/author/pump/</link>
	<description>Rebuilt Refurbished Repaired</description>
	<lastBuildDate>Sun, 03 Oct 2021 05:20:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.2</generator>

<image>
	<url>https://vacuumpumprebuilders.com/wp-content/uploads/2020/06/site_icon_vpr_white-150x150.png</url>
	<title>Super User, Author at Vacuum Pump Rebuilders</title>
	<link>https://vacuumpumprebuilders.com/author/pump/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Stokes 622 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-622-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 10 Mar 2020 03:55:59 +0000</pubDate>
				<category><![CDATA[Stokes Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1053</guid>

					<description><![CDATA[<p>Stokes 622 Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 622 booster pumps offer a pumping speed range from 3000 cfm to 3900 cfm. Stokes 622 (Process Isolation) booster pump is water cooled with 5 mechanical seals for [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-622-booster-pump/">Stokes 622 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="300" height="300" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump-300x300.jpg" alt="Edwards Stokes 622 Booster Pump" class="wp-image-1055 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump-150x150.jpg 150w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-622_booster_pump.jpg 400w" sizes="(max-width: 300px) 100vw, 300px" /></figure><div class="wp-block-media-text__content">
<p><strong>Stokes 622</strong> Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available.  <strong>Stokes 622</strong> booster pumps offer a pumping speed range from 3000 cfm to 3900 cfm. </p>



<p><strong>Stokes 622 (Process Isolation)</strong> booster pump is water cooled with 5 mechanical seals for optimum protection.</p>
</div></div>



<p></p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Stokes 622 Booster Pump Specifications   </h2>



<table id="tablepress-9" class="tablepress tablepress-id-9">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">622</th><th class="column-4">622 PIB<br />
(Process Isolation)<br />
</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 1800 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">N/A</td><td class="column-4">N/A</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 2750 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">5100 | 3000</td><td class="column-4">5100 | 3000</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Displacement 3000 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">5525 | 2350</td><td class="column-4">5525 | 2350</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Displacement 3600 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">6630 | 3900</td><td class="column-4">6630 | 3900</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">8 inch ASA/ANSI</td><td class="column-4">8 inch ASA/ANSI</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Max pressure differential</td><td class="column-2">mbar | torr</td><td class="column-3">333 | 250</td><td class="column-4">333 | 250</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Max temp rise</td><td class="column-2">C | F</td><td class="column-3">121 | 250</td><td class="column-4">121 | 250</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Max discharge temperature</td><td class="column-2">C | F</td><td class="column-3">177 | 350</td><td class="column-4">177 | 350</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Weight bare shaft</td><td class="column-2">kg | lbs</td><td class="column-3">335 | 740</td><td class="column-4">335 | 740</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight TEFC <br />
direct drive</td><td class="column-2">kg | lbs</td><td class="column-3">617 | 1360</td><td class="column-4">625 | 1370</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">18 | 25</td><td class="column-4">18 | 25</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">18 | 25</td><td class="column-4">18 | 25</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Oil capacity <br />
horizontal flow</td><td class="column-2">litre/gal</td><td class="column-3">1.9 | 0.51</td><td class="column-4">1.9 | 0.51</td>
</tr>
<tr class="row-15 odd">
	<td class="column-1">Oil capacity <br />
vertical flow</td><td class="column-2">litre/gal</td><td class="column-3">4.1 | 1.1</td><td class="column-4">4.1 | 1.1</td>
</tr>
<tr class="row-16 even">
	<td class="column-1">Noise level<br />
at 50 Hz</td><td class="column-2">dBA</td><td class="column-3">< 82</td><td class="column-4">< 82</td>
</tr>
</tbody>
</table>
<!-- #tablepress-9 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Stokes 622 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Range of 2750rpm to 3600rpm</li><li>Horizontal or vertical flow configurations</li><li>Noise level &lt;82 dB(A)</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">Stokes 622 Booster Pump Applications</h2>



<ul><li> Automotive</li><li>Chemical processing</li><li>Heat treatment</li><li>Leak detection</li><li>Metallurgy</li><li>PET processing</li><li>Pharmaceuticals</li><li>Thermal processing</li><li>Transformer drying</li><li>Vacuum Coating</li><li>Vacuum melting</li><li>Pharmaceuticals  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf">Stokes Booster Product Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf">Edwards Stokes Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-622-booster-pump/">Stokes 622 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Stokes 615 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-615-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 10 Mar 2020 03:40:10 +0000</pubDate>
				<category><![CDATA[Stokes Booster Pumps]]></category>
		<category><![CDATA[Edwards Vacuum]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1051</guid>

					<description><![CDATA[<p>Stokes 615 Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 615 booster pumps offer a pumping speed range from 1300 cfm to 2600 cfm. Stokes 615 PIB (Process Isolation) booster pump and the Stokes 615 (By-pass) offer a [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-615-booster-pump/">Stokes 615 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump.jpg" alt="Stokes 6 Mechanical Booster Pump" class="wp-image-1047 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes_booster_pump-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Stokes 615</strong> Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available.  <strong>Stokes 615</strong> booster pumps offer a pumping speed range from 1300 cfm to 2600 cfm.  </p>



<p><strong>Stokes 615 PIB (Process Isolation)</strong> booster pump and the <strong>Stokes 615 (By-pass)</strong> offer a pumping speed range from 2000 cfm to 2600 cfm.   </p>
</div></div>



<p></p>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Stokes 615 Booster Pump Specifications   </h2>



<table id="tablepress-8" class="tablepress tablepress-id-8">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">615</th><th class="column-4">615 PIB<br />
(Process Isolation)</th><th class="column-5">615 BP<br />
(By-pass)</th><th class="column-6">615 BP PIB<br />
</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 1800 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">2210 | 1300</td><td class="column-4"> N/A</td><td class="column-5">2210 | 2000</td><td class="column-6">N/A</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 2750 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">3375 | 2000</td><td class="column-4">3375 | 2000</td><td class="column-5">3375 | 2000</td><td class="column-6">3375 | 2000</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Displacement 3000 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">3685 | 2170</td><td class="column-4">3685 | 2170</td><td class="column-5">3685 | 2170</td><td class="column-6">3685 | 2170</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Displacement 3600 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">4420 | 2600</td><td class="column-4">4420 | 2600</td><td class="column-5">4420 | 2600</td><td class="column-6">4420 | 2600</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">8 inch ASA/ANSI</td><td class="column-4">8 inch ASA/ANSI</td><td class="column-5">8 inch ASA/ANSI</td><td class="column-6">8 inch ASA/ANSI</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Max pressure differential</td><td class="column-2">mbar | torr</td><td class="column-3">506 | 380</td><td class="column-4">506 | 380</td><td class="column-5">N/A</td><td class="column-6">N/A</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Max temp rise</td><td class="column-2">C | F</td><td class="column-3">135 | 275</td><td class="column-4">135 | 275</td><td class="column-5">135 | 275</td><td class="column-6">135 | 275</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Max discharge temperature</td><td class="column-2">C | F</td><td class="column-3">191 | 375</td><td class="column-4">191 | 375</td><td class="column-5">191 | 375</td><td class="column-6">191 | 375</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Weight bare shaft</td><td class="column-2">kg | lbs</td><td class="column-3">234 | 515</td><td class="column-4">234 | 515</td><td class="column-5">284 | 625</td><td class="column-6">284 | 625</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight TEFC <br />
direct drive</td><td class="column-2">kg | lbs</td><td class="column-3">390 | 860</td><td class="column-4">297 | 875</td><td class="column-5">530 | 1170</td><td class="column-6">538 | 1185</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10</td><td class="column-4">11 | 15</td><td class="column-5">18 | 25</td><td class="column-6">18 | 25</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">11 | 15</td><td class="column-4">11 | 15</td><td class="column-5">18 | 25</td><td class="column-6">18 | 25</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Oil capacity <br />
horizontal flow</td><td class="column-2">litre/gal</td><td class="column-3">1.9 | 0.51</td><td class="column-4">1.9 | 0.51</td><td class="column-5">1.9 | 0.51</td><td class="column-6">1.9 | 0.51</td>
</tr>
<tr class="row-15 odd">
	<td class="column-1">Oil capacity <br />
vertical flow</td><td class="column-2">litre/gal</td><td class="column-3">4.1 | 1.1</td><td class="column-4">4.1 | 1.1</td><td class="column-5">4.1 | 1.1</td><td class="column-6">4.1 | 1.1</td>
</tr>
<tr class="row-16 even">
	<td class="column-1">Noise level<br />
at 50 Hz</td><td class="column-2">dBA</td><td class="column-3">75</td><td class="column-4">75</td><td class="column-5">< 85</td><td class="column-6">< 85</td>
</tr>
</tbody>
</table>
<!-- #tablepress-8 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Stokes 615 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Range of 180rpm to 3600rpm</li><li>Horizontal or vertical flow configurations</li><li>615 Process Isolation booster model</li><li>615 By-pass booster model</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">Stokes 615 Booster Pump Applications</h2>



<ul><li> Automotive</li><li>Chemical processing</li><li>Heat treatment</li><li>Leak detection</li><li>Metallurgy</li><li>PET processing</li><li>Pharmaceuticals</li><li>Thermal processing</li><li>Transformer drying</li><li>Vacuum Coating</li><li>Vacuum melting</li><li>Pharmaceuticals  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf">Stokes Booster Product Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf">Edwards Stokes Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-615-booster-pump/">Stokes 615 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Stokes 607 Booster Pump</title>
		<link>https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-607-booster-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Tue, 10 Mar 2020 01:20:10 +0000</pubDate>
				<category><![CDATA[Stokes Booster Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[Rugged Design]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1046</guid>

					<description><![CDATA[<p>Stokes 607 Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 607 booster pumps offer a pumping speed range from 612 cfm to 1224 cfm.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-607-booster-pump/">Stokes 607 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump.jpg" alt="Stokes 607 Mechanical Booster Pump" class="wp-image-1054 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Stokes-607_booster_pump-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Stokes 607</strong> Mechanical Booster pumps are rugged designed in bare shaft or direct drive. With Vertical or horizontal gas flow orientation and process isolation versions available. Stokes 607 booster pumps offer a pumping speed range from 612 cfm to 1224 cfm.</p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Stokes 607 Booster Pump Specifications   </h2>



<table id="tablepress-7" class="tablepress tablepress-id-7">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">607</th><th class="column-4">607 PIB<br />
(Process Isolation)</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Displacement 1800 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">1040 | 612</td><td class="column-4"> N/A</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Displacement 2750 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">1589 | 935</td><td class="column-4">1589 | 935</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Displacement 3000 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">1733 | 1020</td><td class="column-4">1733 | 1020</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Displacement 3600 rpm</td><td class="column-2">m3/h | cfm</td><td class="column-3">2080 | 1224</td><td class="column-4">2080 | 1224</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Inlet Connection</td><td class="column-2"></td><td class="column-3">6 inch ASA/ANSI</td><td class="column-4">6 inch ASA/ANSI</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Max pressure differential</td><td class="column-2">mbar | torr</td><td class="column-3">506 | 380</td><td class="column-4">506 | 380</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Max temp rise</td><td class="column-2">C | F</td><td class="column-3">135 | 275</td><td class="column-4">135 | 275</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Max discharge temperature</td><td class="column-2">C | F</td><td class="column-3">191 | 375</td><td class="column-4">191 | 375</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Weight bare shaft</td><td class="column-2">kg | lbs</td><td class="column-3">215 | 475</td><td class="column-4">215 | 475</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight TEFC <br />
direct drive</td><td class="column-2">kg | lbs</td><td class="column-3">408 | 900</td><td class="column-4">408 | 900</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10</td><td class="column-4">7.5 | 10</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10</td><td class="column-4">7.5 | 10</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Oil capacity <br />
horizontal flow</td><td class="column-2">litre/gal</td><td class="column-3">1.9 | 0.51</td><td class="column-4">1.9 | 0.51</td>
</tr>
<tr class="row-15 odd">
	<td class="column-1">Oil capacity <br />
vertical flow</td><td class="column-2">litre/gal</td><td class="column-3">4.1 | 1.1</td><td class="column-4">4.1 | 1.1</td>
</tr>
<tr class="row-16 even">
	<td class="column-1">Noise level<br />
at 50 Hz</td><td class="column-2">dBA</td><td class="column-3">65</td><td class="column-4">70</td>
</tr>
</tbody>
</table>
<!-- #tablepress-7 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Stokes 607 Booster Pump Features </h2>



<ul><li>Bare shaft or direct drive configurations</li><li>Range of 1800rpm to 3600rpm</li><li>Horizontal or vertical flow configurations</li><li>Rugged design</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">Stokes 607 Booster Pump Applications</h2>



<ul><li> Automotive</li><li>Chemical processing</li><li>Heat treatment</li><li>Leak detection</li><li>Metallurgy</li><li>PET processing</li><li>Pharmaceuticals</li><li>Thermal processing</li><li>Transformer drying</li><li>Vacuum Coating</li><li>Vacuum melting</li><li>Pharmaceuticals  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf">Stokes Booster Product Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/stokes-booster-product-manual.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf">Edwards Stokes Mechanical Booster Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2021/09/edwards-stokes-mechanical-booster-pumps-datasheet.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/stokes-booster-pumps/stokes-607-booster-pump/">Stokes 607 Booster Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WS/WSU 2001 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-2001-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 20:32:27 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Hermetically Sealed Motor]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1040</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 2001 Roots vacuum pumps use air cooled hermetically canned motors. The Leybold WSU 2001 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-2001-roots-vacuum-pump/">Leybold WS/WSU 2001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001.jpg" alt="Leybold WS 2001 Roots Vacuum Pump" class="wp-image-992 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_2001-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WS 2001</strong> Roots vacuum pumps use air cooled hermetically canned motors.  The <strong>Leybold WSU 2001</strong> Roots vacuum pumps are provided with an additional integrated pressure equalization line.    </p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 2001 Roots Pump Specifications   </h2>



<table id="tablepress-31" class="tablepress tablepress-id-31">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><65</td>
</tr>
</tbody>
</table>
<!-- #tablepress-31 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 2001 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;65 dB(A)</li><li>IP 20 Protection</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WSU 2001 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>
<!-- #tablepress-17 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-2001-roots-vacuum-pump/">Leybold WS/WSU 2001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WS/WSU 1001 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-1001-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 20:02:39 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Hermetically Sealed Motor]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1037</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 1001 Roots vacuum pumps use air cooled hermetically canned motors. The Leybold WSU 1001 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-1001-roots-vacuum-pump/">Leybold WS/WSU 1001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001.jpg" alt="Leybold WS/WSU 1001 Roots Vacuum Pump" class="wp-image-1000 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_1001-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p> <strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WS 1001 </strong>Roots vacuum pumps use air cooled hermetically canned motors.  The <strong>Leybold WSU 1001 </strong>Roots vacuum pumps are provided with an additional integrated pressure equalization line. <strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 1001 Roots Pump Specifications   </h2>



<table id="tablepress-30" class="tablepress tablepress-id-30">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 1001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1000 | 589</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1200 | 707</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">4.0 | 5.4</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">4.4 | 6.0</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">1.75</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">1.8</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">100 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">228 | 502.7</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">233 | 513.8</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><60</td>
</tr>
</tbody>
</table>
<!-- #tablepress-30 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 1001 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;60 dB(A)</li><li>IP 20 Protection</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WSU 1001 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17-no-2" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-1001-roots-vacuum-pump/">Leybold WS/WSU 1001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WS/WSU 501 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-501-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 19:57:26 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Hermetically Sealed Motor]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1031</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 501 Roots vacuum pumps use air cooled hermetically canned motors. The Leybold WSU 501 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-501-roots-vacuum-pump/">Leybold WS/WSU 501 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501.jpg" alt="Leybold WS/WSU 501 Roots Vacuum Pump" class="wp-image-999 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_501-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WS 501 </strong>Roots vacuum pumps use air cooled hermetically canned motors.  The <strong>Leybold WSU 501 </strong>Roots vacuum pumps are provided with an additional integrated pressure equalization line.    </p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 501 Roots Pump Specifications   </h2>



<table id="tablepress-29" class="tablepress tablepress-id-29">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 501</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">505 | 297.4</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">606 | 357</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">2.4 | 3.3</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.75</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.8</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">130 | 286.7</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">135 | 297.7</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><52</td>
</tr>
</tbody>
</table>
<!-- #tablepress-29 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 501 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;52 dB(A)</li><li>IP 20 Protection</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WSU 501 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17-no-3" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-501-roots-vacuum-pump/">Leybold WS/WSU 501 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WS/WSU 251 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-251-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 19:45:06 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1028</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WS 251 Roots vacuum pumps use air cooled hermetically canned motors . The Leybold WSU 251 Roots vacuum pumps are provided [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-251-roots-vacuum-pump/">Leybold WS/WSU 251 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_251.jpg" alt="Leybold WS/WSU 251 Roots Vacuum Pump" class="wp-image-998 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_251.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_251-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WS_251-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong><strong>Leybold RUVAC </strong></strong>roots pumps are used to increase the  <strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The<strong> Leybold WS 251 </strong>Roots vacuum pumps  use air cooled hermetically canned motors .  The <strong>Leybold WSU 251</strong> Roots vacuum pumps are provided with an additional integrated pressure equalization line.     </p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 251 Roots Pump Specifications   </h2>



<table id="tablepress-28" class="tablepress tablepress-id-28">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td>
</tr>
</tbody>
</table>
<!-- #tablepress-28 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WSU 251 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;8 x 10-4 mbar</li><li>Vertical or horizontal position</li><li>Hermetically canned motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;58 dB(A)</li><li>IP 20 Protection </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WSU 251 Roots  Pump Applications</h2>



<ul><li>Large scale research</li><li>Furnaces</li><li>Metallurgy</li><li>Lamps and tubes manufacturing</li><li>Leak testing systems</li><li>High purity gases/refrigerant cycles</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-17-no-4" class="tablepress tablepress-id-17">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WS/WSU 251</th><th class="column-4">WS/WSU 501</th><th class="column-5">WS/WSU 1001</th><th class="column-6">WS/WSU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power 50 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Motor Power 60 Hz</td><td class="column-2">kW | hp</td><td class="column-3">1.4 | 1.9</td><td class="column-4">2.4 | 3.3</td><td class="column-5">4.4 | 6.0</td><td class="column-6">8.5 | 11.6</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">LVO 400 lube for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.55</td><td class="column-4">.75</td><td class="column-5">1.75</td><td class="column-6">2.7</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Other oil for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Weight WS</td><td class="column-2">kg | lbs</td><td class="column-3">90 | 198.5</td><td class="column-4">130 | 286.7</td><td class="column-5">228 | 502.7</td><td class="column-6">458 | 1009.9</td>
</tr>
<tr class="row-13 odd">
	<td class="column-1">Weight WSU</td><td class="column-2">kg | lbs</td><td class="column-3">95 | 209.5</td><td class="column-4">135 | 297.7</td><td class="column-5">233 | 513.8</td><td class="column-6">465 | 1025.3</td>
</tr>
<tr class="row-14 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><58</td><td class="column-4"><52</td><td class="column-5"><60</td><td class="column-6"><65</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-ws-wsu-251-roots-vacuum-pump/">Leybold WS/WSU 251 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WA/WAU 2001 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-2001-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 19:16:03 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1021</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WA 2001 Roots vacuum pumps use air cooled, flange-mounted standard three phase motors. The Leybold WAU 2001 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-2001-roots-vacuum-pump/">Leybold WA/WAU 2001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p> </p>



<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="600" height="600" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA2001.jpg" alt="Leybold WA/WAU 2001 Roots Vacuum Pump" class="wp-image-997 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA2001.jpg 600w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA2001-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA2001-150x150.jpg 150w" sizes="(max-width: 600px) 100vw, 600px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WA 2001</strong> Roots vacuum pumps use air cooled, flange-mounted standard three phase motors.  The <strong>Leybold WAU 2001</strong> Roots vacuum pumps are provided with an additional integrated pressure equalization line. <strong>   </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WAU 2001 Roots Pump Specifications   </h2>



<table id="tablepress-27" class="tablepress tablepress-id-27">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WA/WAU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power</td><td class="column-2">kW | hp</td><td class="column-3">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lubricant for bearing chamber</td><td class="column-2">litre</td><td class="column-3">3.6</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Lubricant for shaft sealing</td><td class="column-2">litre</td><td class="column-3">1.6</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">160 ISO-K</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">400 | 882</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><72</td>
</tr>
</tbody>
</table>
<!-- #tablepress-27 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WAU 2001 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>3 phase motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;72 dB(A)</li><li>ATEX protection Category 3i </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WAU 2001 Roots  Pump Applications</h2>



<ul><li>VacHeat treatment</li><li>Furnaces</li><li>Metallurgy</li><li>Vacuum coating</li><li>Chemistry</li><li>Packaging</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-16" class="tablepress tablepress-id-16">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WA/WAU 251</th><th class="column-4">WA/WAU 501</th><th class="column-5">WA/WAU 1001</th><th class="column-6">WA/WAU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lubricant for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Lubricant for<br />
shaft sealing</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">1.0</td><td class="column-5">1.3</td><td class="column-6">1.6</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">85 | 187.4</td><td class="column-4">128 | 187.4</td><td class="column-5">220 | 485.1</td><td class="column-6">400 | 882</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><62</td><td class="column-4"><65</td><td class="column-5"><70</td><td class="column-6"><72</td>
</tr>
</tbody>
</table>
<!-- #tablepress-16 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-2001-roots-vacuum-pump/">Leybold WA/WAU 2001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WA/WAU 1001 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-1001-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 19:10:13 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1019</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WA 1001 Roots vacuum pumps use air cooled, flange-mounted standard three phase motors. The Leybold WAU 1001 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-1001-roots-vacuum-pump/">Leybold WA/WAU 1001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p> </p>



<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="600" height="600" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA1001.jpg" alt="Leybold WA/WAU 1001 Roots Vacuum Pump" class="wp-image-996 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA1001.jpg 600w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA1001-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA1001-150x150.jpg 150w" sizes="(max-width: 600px) 100vw, 600px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WA 1001</strong> Roots vacuum pumps use air cooled, flange-mounted standard three phase motors.  The <strong>Leybold WAU 1001</strong> Roots vacuum pumps are provided with an additional integrated pressure equalization line. <strong>  </strong></p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WAU 1001 Roots Pump Specifications   </h2>



<table id="tablepress-26" class="tablepress tablepress-id-26">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WA/WAU 1001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1000 | 589</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">1200 | 707</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power</td><td class="column-2">kW | hp</td><td class="column-3">4.0 | 5.4</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lubricant for bearing chamber</td><td class="column-2">litre</td><td class="column-3">1.8</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Lubricant for shaft sealing</td><td class="column-2">litre</td><td class="column-3">1.3</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">100 ISO-K</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">220 | 485.1</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><70</td>
</tr>
</tbody>
</table>
<!-- #tablepress-26 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WAU 1001 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>3 phase motor</li><li>3000 rpm at @ 50 Hz</li><li>3600 rpm at @ 60 Hz</li><li>Rugged bearings </li><li>Low Noise &lt;70 dB(A)</li><li>ATEX protection Category 3i   </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WAU 1001 Roots  Pump Applications</h2>



<ul><li>VacHeat treatment</li><li>Furnaces</li><li>Metallurgy</li><li>Vacuum coating</li><li>Chemistry</li><li>Packaging</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-16-no-2" class="tablepress tablepress-id-16">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WA/WAU 251</th><th class="column-4">WA/WAU 501</th><th class="column-5">WA/WAU 1001</th><th class="column-6">WA/WAU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lubricant for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Lubricant for<br />
shaft sealing</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">1.0</td><td class="column-5">1.3</td><td class="column-6">1.6</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">85 | 187.4</td><td class="column-4">128 | 187.4</td><td class="column-5">220 | 485.1</td><td class="column-6">400 | 882</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><62</td><td class="column-4"><65</td><td class="column-5"><70</td><td class="column-6"><72</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-1001-roots-vacuum-pump/">Leybold WA/WAU 1001 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Leybold WA/WAU 501 Roots Vacuum Pump</title>
		<link>https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-501-roots-vacuum-pump/</link>
		
		<dc:creator><![CDATA[Super User]]></dc:creator>
		<pubDate>Mon, 09 Mar 2020 19:00:55 +0000</pubDate>
				<category><![CDATA[Leybold Roots Pumps]]></category>
		<category><![CDATA[Roots Blower/Booster Pump]]></category>
		<category><![CDATA[RUVAC]]></category>
		<guid isPermaLink="false">https://vacuumpumprebuilders.com/?p=1015</guid>

					<description><![CDATA[<p>Leybold RUVAC roots pumps are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps. The Leybold WA 501 Roots vacuum pumps use air cooled, flange-mounted standard three phase motors. The Leybold WAU 501 Roots vacuum pumps are provided with an additional integrated pressure equalization line.</p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-501-roots-vacuum-pump/">Leybold WA/WAU 501 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile" style="grid-template-columns:auto 45%"><figure class="wp-block-media-text__media"><img decoding="async" loading="lazy" width="400" height="400" src="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA251.jpg" alt="Leybold RUVAC WA/WAU Roots vacuum pump" class="wp-image-994 size-medium" srcset="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA251.jpg 400w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA251-300x300.jpg 300w, https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_WA251-150x150.jpg 150w" sizes="(max-width: 400px) 100vw, 400px" /></figure><div class="wp-block-media-text__content">
<p><strong>Leybold RUVAC roots pumps</strong> are used to increase the pumping speed at low pressures, extending the operating pressure range of the fore pumps.  The <strong>Leybold WA 501</strong> Roots vacuum pumps use air cooled, flange-mounted standard three phase motors.  The <strong>Leybold WAU 501</strong> Roots vacuum pumps are provided with an additional integrated pressure equalization line.   </p>
</div></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details open><summary class="gb-accordion-title">Specifications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WAU 501 Roots Pump Specifications   </h2>



<table id="tablepress-25" class="tablepress tablepress-id-25">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WA/WAU 501</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed 50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">505 | 297.4</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed 60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">606 | 357</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power</td><td class="column-2">kW | hp</td><td class="column-3">2.2 | 3.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Nominal Speed 50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed 60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lubricant for bearing chamber</td><td class="column-2">litre</td><td class="column-3">.8</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Lubricant for shaft sealing</td><td class="column-2">litre</td><td class="column-3">1.0</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">128 | 187.4</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><65</td>
</tr>
</tbody>
</table>
<!-- #tablepress-25 from cache -->
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Features</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading"> Leybold WAU 501 Roots  Pump Features </h2>



<ul><li>Ultimate total pressure &lt;4 x 10-2 mbar</li><li>Vertical or horizontal position</li><li>3 phase motor</li><li>3000 rpm at @ 50 Hz</li><li> 3600 rpm at @ 60 Hz</li><li> Rugged bearings </li><li>Low Noise &lt;65 dB(A)</li><li>ATEX protection Category 3i  </li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Applications</summary><div class="gb-accordion-text">
<h2 class="has-large-font-size wp-block-heading">   Leybold WAU 501 Roots  Pump Applications</h2>



<ul><li>VacHeat treatment</li><li>Furnaces</li><li>Metallurgy</li><li>Vacuum coating</li><li>Chemistry</li><li>Packaging</li><li>Central vacuum supply systems</li><li>Freeze drying</li><li>Electrical engineering</li><li>Mechanical engineering</li><li>Automotive industry</li></ul>
</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Compare</summary><div class="gb-accordion-text">
<table id="tablepress-16-no-3" class="tablepress tablepress-id-16">
<thead>
<tr class="row-1 odd">
	<th class="column-1">Model</th><th class="column-2"></th><th class="column-3">WA/WAU 251</th><th class="column-4">WA/WAU 501</th><th class="column-5">WA/WAU 1001</th><th class="column-6">WA/WAU 2001</th>
</tr>
</thead>
<tbody class="row-hover">
<tr class="row-2 even">
	<td class="column-1">Pumping Speed <br />
50 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">253 | 149</td><td class="column-4">505 | 297.4</td><td class="column-5">1000 | 589</td><td class="column-6">2050 | 1207.5</td>
</tr>
<tr class="row-3 odd">
	<td class="column-1">Pumping Speed <br />
60 Hz</td><td class="column-2">m3/h | cfm</td><td class="column-3">304 | 179</td><td class="column-4">606 | 357</td><td class="column-5">1200 | 707</td><td class="column-6">2460 | 1449</td>
</tr>
<tr class="row-4 even">
	<td class="column-1">Ultimate Pressure</td><td class="column-2">mbar</td><td class="column-3"><8 x 10^4</td><td class="column-4"><4 x 10^2</td><td class="column-5"><4 x 10^2</td><td class="column-6"><4 x 10^2</td>
</tr>
<tr class="row-5 odd">
	<td class="column-1">Motor Power</td><td class="column-2">kW | hp</td><td class="column-3">1.1 | 1.5</td><td class="column-4">2.2 | 3.0</td><td class="column-5">4.0 | 5.4</td><td class="column-6">7.5 | 10.0</td>
</tr>
<tr class="row-6 even">
	<td class="column-1">Nominal Speed <br />
50Hz</td><td class="column-2">rpm</td><td class="column-3">3000</td><td class="column-4">3000</td><td class="column-5">3000</td><td class="column-6">3000</td>
</tr>
<tr class="row-7 odd">
	<td class="column-1">Nominal Speed <br />
60Hz</td><td class="column-2">rpm</td><td class="column-3">3600</td><td class="column-4">3600</td><td class="column-5">3600</td><td class="column-6">3600</td>
</tr>
<tr class="row-8 even">
	<td class="column-1">Lubricant for<br />
bearing chamber</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">.8</td><td class="column-5">1.8</td><td class="column-6">3.6</td>
</tr>
<tr class="row-9 odd">
	<td class="column-1">Lubricant for<br />
shaft sealing</td><td class="column-2">litre</td><td class="column-3">.6</td><td class="column-4">1.0</td><td class="column-5">1.3</td><td class="column-6">1.6</td>
</tr>
<tr class="row-10 even">
	<td class="column-1">Connection Flange</td><td class="column-2">DN</td><td class="column-3">63 ISO-K</td><td class="column-4">63 ISO-K</td><td class="column-5">100 ISO-K</td><td class="column-6">160 ISO-K</td>
</tr>
<tr class="row-11 odd">
	<td class="column-1">Weight</td><td class="column-2">kg | lbs</td><td class="column-3">85 | 187.4</td><td class="column-4">128 | 187.4</td><td class="column-5">220 | 485.1</td><td class="column-6">400 | 882</td>
</tr>
<tr class="row-12 even">
	<td class="column-1">Noise Level @ 50 Hz</td><td class="column-2">dB(A)</td><td class="column-3"><62</td><td class="column-4"><65</td><td class="column-5"><70</td><td class="column-6"><72</td>
</tr>
</tbody>
</table>

</div></details></div>



<div class="wp-block-genesis-blocks-gb-accordion gb-block-accordion"><details><summary class="gb-accordion-title">Manual</summary><div class="gb-accordion-text">
<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf">Leybold Roots Pumps Datasheet</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pumps_datasheet.pdf" class="wp-block-file__button" download>Download</a></div>



<div class="wp-block-file"><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf">Leybold Roots Pumps Manual</a><a href="https://vacuumpumprebuilders.com/wp-content/uploads/2020/03/Leybold_roots_pump_brochure.pdf" class="wp-block-file__button" download>Download</a></div>
</div></details></div>



<p></p>
<p>The post <a rel="nofollow" href="https://vacuumpumprebuilders.com/leybold-roots-pumps/leybold-wa-wau-501-roots-vacuum-pump/">Leybold WA/WAU 501 Roots Vacuum Pump</a> appeared first on <a rel="nofollow" href="https://vacuumpumprebuilders.com">Vacuum Pump Rebuilders</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
